Astra Wireless Documentation
  • Technical documentation
    • Astra Quanta⁣ Technical User Manual
      • Introduction⁣⁣⁣⁣⁣⁣⁣
        • Key Features⁣⁣⁣⁣⁣
        • Hardware Platform⁣⁣⁣⁣⁣
        • Power Supply⁣⁣⁣⁣⁣⁣
        • Lightning⁣ ⁣protection unit⁣⁣⁣⁣⁣
        • Packing list⁣⁣⁣⁣⁣⁣⁣
      • Planning considerations⁣⁣⁣⁣⁣⁣⁣
      • Link pre-configuration in the lab⁣⁣⁣⁣⁣
      • Installation
      • Operation & Administration⁣⁣⁣⁣⁣
        • Web GUI access⁣⁣⁣⁣
        • Dashboard⁣⁣⁣⁣
        • General settings⁣⁣⁣⁣⁣
        • Security settings⁣⁣⁣⁣
        • Radio settings⁣⁣⁣⁣
        • Network settings⁣⁣⁣⁣⁣
        • Switch Settings
        • SNMP settings⁣⁣⁣⁣
        • Spectrum Analyzer⁣⁣⁣⁣⁣
        • Antenna Alignment Tool⁣⁣⁣⁣⁣
        • Maintenance⁣⁣⁣
        • Instant DFS⁣⁣⁣⁣
        • Graphs⁣⁣⁣⁣
      • Troubleshooting⁣⁣⁣⁣⁣⁣⁣⁣⁣
    • Astra Evolution Technical User Manual
      • Introduction⁣⁣⁣⁣⁣⁣
        • Key Features⁣⁣⁣⁣⁣⁣⁣
        • Hardware Platform⁣⁣⁣⁣⁣⁣⁣⁣
        • Power supply⁣⁣⁣⁣⁣⁣⁣
        • Lightning protection unit⁣⁣⁣⁣⁣⁣⁣⁣⁣⁣⁣
        • Synchronization unit⁣⁣⁣⁣⁣⁣⁣
        • ⁣⁣⁣Packing List
      • Planning considerations⁣⁣⁣⁣⁣⁣⁣⁣⁣
      • Link Pre-configuration in the lab⁣⁣⁣⁣⁣⁣⁣⁣⁣
      • Installation⁣⁣⁣⁣⁣
      • Operation & Administration⁣⁣⁣⁣⁣⁣⁣
        • Web GUI access⁣⁣⁣⁣⁣⁣
        • Device Status⁣⁣
        • Basic Settings⁣⁣⁣⁣⁣
          • System Settings⁣⁣⁣⁣⁣⁣
          • Network Settings⁣⁣⁣⁣⁣⁣⁣
          • Link Settings⁣⁣⁣⁣⁣⁣
          • Static Links⁣⁣⁣⁣⁣
          • MAC Switch⁣ ⁣
          • IP Firewall
          • SNMP
          • QoS Options⁣⁣⁣⁣⁣⁣
          • Traffic Shaping⁣⁣⁣⁣⁣⁣⁣
          • Extra Commands⁣⁣⁣⁣⁣⁣
        • Maintenance
        • Spectrum Analyzer
        • DFS
        • Command Line
      • Troubleshooting⁣⁣⁣⁣⁣⁣
        • No access to the local unit⁣⁣⁣⁣⁣
        • The wireless link cannot be established⁣⁣⁣⁣⁣
        • The wireless link is established, but there is no access to the remote device⁣⁣⁣
        • The wireless link throughput is lower than expected⁣⁣⁣
        • Common errors in configuration⁣⁣⁣⁣
        • Emergence Repair Console⁣⁣
        • Unicast-flood detection⁣⁣⁣⁣
    • AstraFleX⁣ Technical User Manual
      • Getting started with AstraFleX User Manual
      • ⁣⁣IP-address format
      • General Purpose Command Set
      • Layer 2 commands set -PHY and MAC
        • ⁣prf ⁣command
        • ⁣⁣lag command (Link Aggregation )
        • ⁣⁣svi command
        • ⁣⁣ltest (radio link test)
        • macf command (addresses mapping)
        • ⁣⁣arp command (ARP protocol)
        • ⁣⁣switch command
        • ⁣⁣dfs (Dynamic Frequency Selection)
        • ⁣⁣lldp command
        • ⁣⁣mint command
        • ⁣⁣rfconfig command
      • ⁣⁣Layer 3 Command set – IP Networking
        • ⁣⁣Ifconfig command (interfaces configuration)
        • tun command (tunnels building)
        • qm command (QoS configuration)
        • ⁣⁣route command (static routes configuration)
        • ⁣⁣arip command
        • ⁣⁣OSPF command
        • ARDA (Aqua Router DAemon)
        • ⁣⁣netstat command (Network statistics)
        • ⁣⁣ipfw command (IP Firewall)
          • ⁣⁣PCAP-filters
        • ⁣⁣loadm command (load meter)
        • ⁣⁣rpcapd command (Remote Packet Capture)
        • ⁣⁣snmpd command (SNMP daemon)
        • ⁣⁣td command (Telnet daemon)
        • ⁣⁣nat command (Network Address Translation)
        • ⁣⁣trapd command (SNMP Traps support)
        • dhcpd command (DHCP Server)
        • ⁣⁣dhcpr command (DHCP relay)
        • dhcpc command (DHCP Client)
        • ⁣⁣vrrp command (VRRP server)
      • ⁣⁣Other commands
    • ⁣NEXT Monitoring System Technical User Manual
      • Description⁣ and operational principles
      • Installation
      • Configuration⁣⁣ ⁣and⁣ management⁣
        • Wireless⁣ ⁣⁣devices preparation
        • Accounts⁣ and user groups
        • Devices⁣ ⁣and links
        • Incident⁣ ⁣⁣management
        • System⁣⁣ ⁣configuration
      • Monitoring⁣ ⁣and management
        • R⁣ep⁣o⁣⁣rts
        • Devices
        • ⁣⁣Incidents
        • MAP
      • Technical support
  • White⁣ papers
    • MINT ⁣⁣⁣technology
    • Dynamic ⁣⁣Frequency ⁣⁣Selection
    • ⁣⁣RADIUS authentication for admin users
    • Security in Astra Wireless Devices
    • ⁣⁣Performance of the Astra Wireless devices
      • Astra Quanta
        • ⁣⁣Thr⁣⁣⁣oughpu⁣t⁣⁣⁣⁣⁣⁣
        • ⁣Packet ⁣⁣performanc⁣e⁣⁣⁣⁣⁣
      • Astra Evolution
        • H22 platform
          • Packet ⁣⁣⁣perfor⁣mance⁣⁣
          • Throug⁣hput⁣⁣⁣⁣⁣⁣
        • H16 platform
          • Packet⁣⁣ ⁣perfor⁣mance⁣⁣
          • ⁣⁣⁣⁣⁣⁣Throug⁣hput⁣⁣⁣⁣⁣⁣⁣
    • ⁣⁣⁣Link ⁣⁣⁣aggregation, balancing and redundancy
      • Astra Evolution
        • Redundancy ⁣⁣⁣with Failover option
        • Redundancy w/o aggregation and AstraMUX
        • Redundancy⁣⁣⁣ ⁣with aggregation and w/o AstraMUX
        • Redundancy ⁣⁣with AstraMUX
        • Full⁣ Duplex
      • Astra Quanta
        • Aggregation ⁣with redundancy ⁣based on⁣ LACP
        • Redundancy⁣⁣⁣ ⁣based ⁣on STP
        • ⁣Redundancy⁣⁣ based on⁣ OSPF
        • ⁣Redundancy with Evolution
    • Beamforming⁣ ⁣technology
    • ⁣⁣⁣Remote ⁣⁣⁣L2 management of Evolution via CLI
    • ⁣⁣⁣Remote ⁣⁣⁣L2 management of Evolution via Web GUI
    • Connectivity with mobile objects⁣⁣⁣⁣
      • Mining industry⁣⁣⁣
      • Railway transport⁣⁣⁣
      • Transport over the water⁣⁣⁣
      • Configuration example⁣⁣⁣
Powered by GitBook

Astra Wireless Technology © 2024. All rights reserved. For more information about available models, sales and technical support, please proceed to https://astrawireless.net/

On this page
  • Indoor AC/DC injector IDU-CPE-G(24W)
  • Indoor AC/DC injector IDU-CPE-G(56W)
  • Indoor DC/DC injector for all Astra Wireless' units with integrated lightning protection IDU-LA-G(V.01)
  • Lightning Protection Unit with Injector AUX-ODU-INJ-G
  1. Technical documentation
  2. Astra Evolution Technical User Manual
  3. Introduction⁣⁣⁣⁣⁣⁣

Power supply⁣⁣⁣⁣⁣⁣⁣

PreviousHardware Platform⁣⁣⁣⁣⁣⁣⁣⁣NextLightning protection unit⁣⁣⁣⁣⁣⁣⁣⁣⁣⁣⁣

Last updated 1 year ago

Indoor AC/DC injector IDU-CPE-G(24W)

IDU-CPE-G(24W) is an indoor Gigabit PoE injector which supports 100-240 V input range from the AC mains. IDU-CPE-G(24W) feeds 48 VDC power to the device by injecting it to the CAT5 Ethernet cable.

Parameter
Description

Compatible models

Astra Quanta and Astra Evolution (except E5-BSQ), AUX-ODU-SYNC

Size and weight

9753.533.5 mm, 0.133 kg

Connectors and Interfaces

  • "LAN" - Ethernet input (Data only)

  • "POE" - Ethernet output (Data+VDC), PASSIVE PoE

  • "PWR" - AC Input

Supported Ethernet Modes

10/100/1000 Mbps

Standards

  • IEEE 802.3 10Base-T

  • IEEE 802.3U 100Base-TX

  • IEEE 802.3ab 1000Base-T

Input Power Requirements

  • AC Input Voltage: 100 ... 240 VAC

  • AC Input Current: 0.75 A

  • AC Frequency: 50 to 60 Hz

Consumption

28 W

Operating temperature range

-10 °С ... +40 °С

Operating humidity

Maximum 95 %, Non-condensing

Storage temperature

-40 °С ... +70 °С

Output Power Voltage

48 VDC, 0.5 A

Safety

UL cUL, CE, GS, CCC, FCC, S-MARK, PSE, C-tick, KC(48V0.5A) BIS(24V1A

Ethernet Connectors Pin-out

Pin
LAN
POE

1

A+

A+

2

A-

A-

3

B+

B+

4

C+

C+

5

C-

+VDC/ C-

6

B-

B-

7

D+

-VDC / D+

8

D-

-VDC / D-

Indoor AC/DC injector IDU-CPE-G(56W)

IDU-CPE-G(56W) is an indoor AC/DC PoE injector with built-in lightning protection. PoE injector is powered by an AC supply in the 100-240 V range.

Parameter
Description

Compatible models

Astra Quanta, Astra Evolution

Connectors and Interfaces

  • "LAN" - Ethernet input (Data only)

  • "POE" - Ethernet output (Data+VDC), PASSIVE PoE

  • "PWR" - AC Input

Consumption

  • 60 W over 4-pairs (Guaranteed)

EMC

Meet:

  • FCC Part 15, Class B

Input Voltage

  • 100 ... 240 V

Lightning Protection

In compliance with:

  • IEC 61000-4-2 (ESD) 15kV (air), 8kV (contact)

  • IEC 61000-4-4 (EFT) 40A (tp = 5/50ns)

  • IEC 61000-4-5 (Lightning) L5, 95A (tp = 8/20us)

Operating temperature range

  • 0 °С ... +40 °С

Output Voltage & Current

  • +56 V, 1 A

Pin Assignment and Polarity

  • 1/2 (+) and 3/6 (-)

  • 4/5 (+) and 7/8 (-)

Size

137.5*62.5*33 mm (L*W*H)

Supported Ethernet Modes

  • 10/100/1000Mbps (Gigabit Ethernet pass-through)

Weight

0.24 kg

Indoor DC/DC injector for all Astra Wireless' units with integrated lightning protection IDU-LA-G(V.01)

IDU-LA-G(V.01) is an indoor DC/DC injector. It greatly reduces complexity of the deployment in the cases where DC source is available thus reducing both capital expenditures and total cost of ownership.

IDU-LA-G(V.01) may be used for the following purposes:

  • To serve as a line protection unit for indoor network equipment connected to the second Ethernet port on ODU.

  • To connect third-party DC power sources to ODU (for example, to power the unit from solar power or wind power sources).

Technical parameters

Parameter
Description

Compatible models

Astra Quanta, Astra Evolution

Output Voltage

The same as input

Supported Ethernet Modes

10/100/1000 Mbps (Gigabit Ethernet pass-through)

Pin assignment and polarity

1/2 (+), 3/6 (-), 4/5 (+), 7/8 (-)

Size and Weight

115×65×40 mm, 0.15 kg

Operating temperature range

From 0°С to +40°С

CAUTION

Exposing unit to the unsupported voltage will result in irreparable damage to the unit! Always observe power requirements!

Connectors description

Mounting holes sizes

IDU-LA-G(V.01) Packing List

Cable assembly

Lightning Protection Unit with Injector AUX-ODU-INJ-G

Optional indoor/outdoor DC injector with built-in lightning protection. It greatly reduces complexity of the deployment in the cases where DC source is available on the rooftop eliminating the need of weather-sealed cabinets. AUX-ODU-INJ-G is compatible with all Astra Wireless devices.

Parameter
Description

Size and Weight

34x94x121 mm, 0.28 kg

Connectors and Interfaces

  • ETH IN - Ethernet input

  • ETH OUT - Ethernet output (data+VDC, protected leg)

  • PWR - DC Input

  • GND - Ground clamp

Supported Ethernet Modes

10/100/1000 Mbps (Gigabit Ethernet pass-through)

Water and Dust Protection

IP66 and IP67

Operating temperature range

-55 °C ... +60 ºC

DC Range

±43...±56 VDC

Lightning Protection

In compliance with:

  • GR-1089

  • IEC 61000-4-2 (ESD) 15kV (air), 8kV (contact)

  • IEC 61000-4-4 (EFT) 40A (tp = 5/50ns)

  • IEC 61000-4-5 (Lightning) L5, 95A (tp = 8/20us)

  • ETSI ETS 300 386

CAUTION

Using inappropriate DC source will damage the ODU, which will be not covered by warranty

Ethernet Connectors Pin-out

Pin
LAN
POE

1

Data pair A+

Data pair A+

2

Data pair A-

Data pair A-

3

Data pair B+

Data pair B+

4

Data pair C-

+VDC + Data pair C-

5

Data pair C+

+VDC + Data pair C+

6

Data pair B-

Data pair B-

7

Data pair D+

-VDC + Data pair D+

8

Data pair D-

-VDC + Data pair D-

Packing List

AUX-ODU-INJ-G is supplied with a worm clamp TORRO 40-60/9 C7 W4 DIN 3017 - 2 pcs. The clamp is made of stainless steel A4, width 9 mm, allows the installation on a mast with a diameter of 35 to 60 mm. In case of mast diameter more than 60 mm, a similar clamps (up to a 230 mm diameter) with a width of up to 12-13 mm can be used.