Astra Wireless Documentation
  • Technical documentation
    • Astra Quanta⁣ Technical User Manual
      • Introduction⁣⁣⁣⁣⁣⁣⁣
        • Key Features⁣⁣⁣⁣⁣
        • Hardware Platform⁣⁣⁣⁣⁣
        • Power Supply⁣⁣⁣⁣⁣⁣
        • Lightning⁣ ⁣protection unit⁣⁣⁣⁣⁣
        • Packing list⁣⁣⁣⁣⁣⁣⁣
      • Planning considerations⁣⁣⁣⁣⁣⁣⁣
      • Link pre-configuration in the lab⁣⁣⁣⁣⁣
      • Installation
      • Operation & Administration⁣⁣⁣⁣⁣
        • Web GUI access⁣⁣⁣⁣
        • Dashboard⁣⁣⁣⁣
        • General settings⁣⁣⁣⁣⁣
        • Security settings⁣⁣⁣⁣
        • Radio settings⁣⁣⁣⁣
        • Network settings⁣⁣⁣⁣⁣
        • Switch Settings
        • SNMP settings⁣⁣⁣⁣
        • Spectrum Analyzer⁣⁣⁣⁣⁣
        • Antenna Alignment Tool⁣⁣⁣⁣⁣
        • Maintenance⁣⁣⁣
        • Instant DFS⁣⁣⁣⁣
        • Graphs⁣⁣⁣⁣
      • Troubleshooting⁣⁣⁣⁣⁣⁣⁣⁣⁣
    • Astra Evolution Technical User Manual
      • Introduction⁣⁣⁣⁣⁣⁣
        • Key Features⁣⁣⁣⁣⁣⁣⁣
        • Hardware Platform⁣⁣⁣⁣⁣⁣⁣⁣
        • Power supply⁣⁣⁣⁣⁣⁣⁣
        • Lightning protection unit⁣⁣⁣⁣⁣⁣⁣⁣⁣⁣⁣
        • Synchronization unit⁣⁣⁣⁣⁣⁣⁣
        • ⁣⁣⁣Packing List
      • Planning considerations⁣⁣⁣⁣⁣⁣⁣⁣⁣
      • Link Pre-configuration in the lab⁣⁣⁣⁣⁣⁣⁣⁣⁣
      • Installation⁣⁣⁣⁣⁣
      • Operation & Administration⁣⁣⁣⁣⁣⁣⁣
        • Web GUI access⁣⁣⁣⁣⁣⁣
        • Device Status⁣⁣
        • Basic Settings⁣⁣⁣⁣⁣
          • System Settings⁣⁣⁣⁣⁣⁣
          • Network Settings⁣⁣⁣⁣⁣⁣⁣
          • Link Settings⁣⁣⁣⁣⁣⁣
          • Static Links⁣⁣⁣⁣⁣
          • MAC Switch⁣ ⁣
          • IP Firewall
          • SNMP
          • QoS Options⁣⁣⁣⁣⁣⁣
          • Traffic Shaping⁣⁣⁣⁣⁣⁣⁣
          • Extra Commands⁣⁣⁣⁣⁣⁣
        • Maintenance
        • Spectrum Analyzer
        • DFS
        • Command Line
      • Troubleshooting⁣⁣⁣⁣⁣⁣
        • No access to the local unit⁣⁣⁣⁣⁣
        • The wireless link cannot be established⁣⁣⁣⁣⁣
        • The wireless link is established, but there is no access to the remote device⁣⁣⁣
        • The wireless link throughput is lower than expected⁣⁣⁣
        • Common errors in configuration⁣⁣⁣⁣
        • Emergence Repair Console⁣⁣
        • Unicast-flood detection⁣⁣⁣⁣
    • AstraFleX⁣ Technical User Manual
      • Getting started with AstraFleX User Manual
      • ⁣⁣IP-address format
      • General Purpose Command Set
      • Layer 2 commands set -PHY and MAC
        • ⁣prf ⁣command
        • ⁣⁣lag command (Link Aggregation )
        • ⁣⁣svi command
        • ⁣⁣ltest (radio link test)
        • macf command (addresses mapping)
        • ⁣⁣arp command (ARP protocol)
        • ⁣⁣switch command
        • ⁣⁣dfs (Dynamic Frequency Selection)
        • ⁣⁣lldp command
        • ⁣⁣mint command
        • ⁣⁣rfconfig command
      • ⁣⁣Layer 3 Command set – IP Networking
        • ⁣⁣Ifconfig command (interfaces configuration)
        • tun command (tunnels building)
        • qm command (QoS configuration)
        • ⁣⁣route command (static routes configuration)
        • ⁣⁣arip command
        • ⁣⁣OSPF command
        • ARDA (Aqua Router DAemon)
        • ⁣⁣netstat command (Network statistics)
        • ⁣⁣ipfw command (IP Firewall)
          • ⁣⁣PCAP-filters
        • ⁣⁣loadm command (load meter)
        • ⁣⁣rpcapd command (Remote Packet Capture)
        • ⁣⁣snmpd command (SNMP daemon)
        • ⁣⁣td command (Telnet daemon)
        • ⁣⁣nat command (Network Address Translation)
        • ⁣⁣trapd command (SNMP Traps support)
        • dhcpd command (DHCP Server)
        • ⁣⁣dhcpr command (DHCP relay)
        • dhcpc command (DHCP Client)
        • ⁣⁣vrrp command (VRRP server)
      • ⁣⁣Other commands
    • ⁣NEXT Monitoring System Technical User Manual
      • Description⁣ and operational principles
      • Installation
      • Configuration⁣⁣ ⁣and⁣ management⁣
        • Wireless⁣ ⁣⁣devices preparation
        • Accounts⁣ and user groups
        • Devices⁣ ⁣and links
        • Incident⁣ ⁣⁣management
        • System⁣⁣ ⁣configuration
      • Monitoring⁣ ⁣and management
        • R⁣ep⁣o⁣⁣rts
        • Devices
        • ⁣⁣Incidents
        • MAP
      • Technical support
  • White⁣ papers
    • MINT ⁣⁣⁣technology
    • Dynamic ⁣⁣Frequency ⁣⁣Selection
    • ⁣⁣RADIUS authentication for admin users
    • Security in Astra Wireless Devices
    • ⁣⁣Performance of the Astra Wireless devices
      • Astra Quanta
        • ⁣⁣Thr⁣⁣⁣oughpu⁣t⁣⁣⁣⁣⁣⁣
        • ⁣Packet ⁣⁣performanc⁣e⁣⁣⁣⁣⁣
      • Astra Evolution
        • H22 platform
          • Packet ⁣⁣⁣perfor⁣mance⁣⁣
          • Throug⁣hput⁣⁣⁣⁣⁣⁣
        • H16 platform
          • Packet⁣⁣ ⁣perfor⁣mance⁣⁣
          • ⁣⁣⁣⁣⁣⁣Throug⁣hput⁣⁣⁣⁣⁣⁣⁣
    • ⁣⁣⁣Link ⁣⁣⁣aggregation, balancing and redundancy
      • Astra Evolution
        • Redundancy ⁣⁣⁣with Failover option
        • Redundancy w/o aggregation and AstraMUX
        • Redundancy⁣⁣⁣ ⁣with aggregation and w/o AstraMUX
        • Redundancy ⁣⁣with AstraMUX
        • Full⁣ Duplex
      • Astra Quanta
        • Aggregation ⁣with redundancy ⁣based on⁣ LACP
        • Redundancy⁣⁣⁣ ⁣based ⁣on STP
        • ⁣Redundancy⁣⁣ based on⁣ OSPF
        • ⁣Redundancy with Evolution
    • Beamforming⁣ ⁣technology
    • ⁣⁣⁣Remote ⁣⁣⁣L2 management of Evolution via CLI
    • ⁣⁣⁣Remote ⁣⁣⁣L2 management of Evolution via Web GUI
    • Connectivity with mobile objects⁣⁣⁣⁣
      • Mining industry⁣⁣⁣
      • Railway transport⁣⁣⁣
      • Transport over the water⁣⁣⁣
      • Configuration example⁣⁣⁣
Powered by GitBook

Astra Wireless Technology © 2024. All rights reserved. For more information about available models, sales and technical support, please proceed to https://astrawireless.net/

On this page
  • Firmware
  • SSL certificate installation
  • Firmware update
  • Mass firmware upgrade
  • Upload
  • Download
  • Bottom section of the page
  1. Technical documentation
  2. Astra Evolution Technical User Manual
  3. Operation & Administration⁣⁣⁣⁣⁣⁣⁣

Maintenance

PreviousExtra Commands⁣⁣⁣⁣⁣⁣NextSpectrum Analyzer

Last updated 1 year ago

The "Maintenance" menu allows you to perform service tasks for the device maintenance and to check the hardware and software version, reason for the last reboot, system uptime, current configuration, license, diagnostic card, etc.

Firmware

Parameter
Description

Firmware Version

Displays the current firmware version.

The firmware string contains also the hardware platform type.

Build Date

Displays the firmware build date.

Serial Number

Displays the serial number of the unit.

Part Number

Displays the part number of the unit.

It contains information about the unit type.

Platform

Displays the processor model.

Uptime

Displays the system up time since the last reboot.

Last Reboot Reason

Displays the reason for the last reboot of the unit.

The options are:

  • Software fault

  • Unexpected restart

  • Manual restart

  • Manual delayed restart

  • Firmware upgrade

  • SNMP managed restart

  • Test firmware loaded

SSL certificate installation

NOTE

To configure a wireless device via Web GUI using secure protocol HTTPS, a SSL certificate must be installed as trusted into your web browser. Otherwise, the automatic update function will not be available.

The following description shows an installation process for Google Chrome web browser. Configuration of other web browsers is described in the relevant product user guide and is similar to following.

  1. Download SSL certificate by clicking the "Install Certificate for upgrade firmware via SSL" link. Please note, this link is available if you connect to the Web GUI via HTTPS only.

  2. Open the "Chrome Settings" section and click on the "Manage certificates" button.

  1. Click the "Import..." button to launch Certificate Import Wizard.

  2. Follow the wizard's instructions and choose the file to be imported. Click the "Browse..." button and choose the SSL certificate that you have downloaded before. Click the "Next" button to proceed.

  3. In the next step it is necessary to select the repository where certificate will be placed. All new certificates are installed into the personal repository by default, click on the "Browse..." button and select "Trusted Root Certification Authorities". Click the "Next" button to proceed.

  1. Final step is to check all the provided information. Click the "Finish" button if it's correct. The security warning will appear, click the "Yes" button to confirm you really want to install the certificate.

Firmware update

The firmware can be updated in two ways: automatically and manually.

Automatic update

The system checks automatically for the firmware updates on the Astra Wireless repository and displays a warning message for 10s at each login to the Web interface if a new software version is available:

NOTE

It is not mandatory for the unit to have access to the Internet for this feature to work. However, the PC that is used to initialize the upgrade procedure must have access to Astra Wireless website (both http and ftp).

In case of new software version availability, after clicking the «Check Latest Release» button, the system provides the following options:

By clicking the «Upgrade Firmware» button, the system starts the firmware upgrade process automatically.

After the firmware upgrade process ends, you have to reboot the unit before using the new software version.

By clicking the «Save New Firmware» button, you download the new firmware file locally on your PC.

If no new firmware version is available, the system provides a full change log for the latest firmware release after clicking the «Check Latest Release» button. The process above is the same in case of Beta firmware version. Click the «Check Latest Beta» button for it.

Manual update

In case the PC does not have an access to the Internet, the device must be updated manually. To do this, proceed to the following steps:

  1. Choose the downloaded firmware file in the "Upload" section.

  2. Click the "Upload" button. The upgrade process will be started.

Mass firmware upgrade

Each device has the ability to mass firmware upgrade using OTA (Over the Air) function. The firmware can be distributed to:

  • All devices within a single MINT domain. The firmware will be applied even to the not directly connected devices.

  • Neighbor devices, directly connected to the current.

NOTE

Only one firmware version can be applied during one mass upgrade cycle. The uploaded firmware version will be applied only to those devices that are built on the same platform. Thus if the upgraded network includes devices on different platforms, the mass upgrade cycle should be performed for each platform.

In case the OTA function is enabled the uploaded firmware will not be applied to the device from which the upgrade is performed. It will be uploaded only to the other network devices.

Mass upgrade cycle includes the following steps:

  1. Download the required firmware version from the official FTP server.

  2. Choose the downloaded firmware file in the "Upload" section. Enable OTA function. Enable "Neighbors only" in case you want to upgrade only the neighbor devices.

  1. Click the "Upload" button. The mass upgrade process will be started.

Mass upgrade monitoring

The remote devices will be rebooted after upgrade completion. The connection failure duration is approximately 35-40 seconds per device.

Upload

The "Upload" section allows you to upload other license, firmware and configuration files to the unit.

For each of the three options, click the «Choose File» button, followed by the «Upload» button after the file has been picked up.

After clicking the «Upload» button, the system performs three operations: uploading, saving and validating the new file uploaded and indicates if each of the operation succeeded or failed. In case that the process succeeded, you have to reboot the unit in order to apply the new changes.

Download

The "Download" section allows you to download locally, to the management PC, the current license, firmware and configuration files, by clicking the corresponding buttons: «Download License», «Download Firmware» and «Download Configuration».

Bottom section of the page

The following buttons are available:

  • «Reboot» - reboots the device. A warning message pops up asking for the permission before the operation to start. During the restart process, you are redirected to the login page and the timeout period of 35 seconds counts down before the new login:

  • «Restore Factory Settings» - restores the factory default configuration. A warning message pops up, asking for the permission before the operation to start. During the reset to factory process, you are redirected to the login page and the timeout period of 30 seconds counts down before the new login:

  • «View Current License» - shows the current device license parameters in a new window

  • «View Current Configuration» - shows the current device configuration in text format in a new window

  • «Create Diagnostic Card» - Tech Support Reports Generator. By clicking this button, the system downloads to the local PC a text file that contains the complete information (for the technical support specialists) set from the device such as: full device configuration listing, system log output, license information, “mint map detail” command output, interfaces statistics, etc.

Download the required firmware version in advance from the official FTP server . Pay attention to the hardware platform of the device being updated, indicated in the Firmware section.

The mass upgrade progress can be seen in the System Log ( section): the number of upgraded devices and progress.

https://ftp.astrawireless.net/pub/Firmware
Device Status