Link Pre-configuration in the lab⁣⁣⁣⁣⁣⁣⁣⁣⁣

Usually, before going into the field, it is recommended to pre-configure in the lab the Astra Wireless units to verify the link establishment. Take the units out of the package and place them on the table.

Step 1: Scheme connection assembling

The equipment list required for the lab configuration:

  1. Outdoor units - 2 pcs.

  2. Power supply - 2 pcs.

  3. Power cord - 2 pcs.

  4. Ethernet cables - 4 pcs.

  5. Laptop with Ethernet port available.

We will perform the settings mentioned below for each unit and check if the wireless link was established correctly.

Use the following instruction to assemble a test scheme:

  1. Connect Gigabit Ethernet port at the ODU to the power supply port labeled as "OUT".

  2. Connect Ethernet port at the laptop to the power supply port labeled as "IN".

  3. Connect the power cord to power supply and plug it to AC mains.

Step 2: Access to the device

Let's access each unit to the default IP address 10.10.10.1 with mask 255.255.255.0 via a web browser. Before, make sure the Ethernet port of the Laptop has an IP address assigned from the same subnetwork as the one for the unit (e.g., set 10.10.10.10 with mask 255.255.255.0).

Use any letters or numbers for the initial authentication on each unit, for example:

  • Login: login.

  • Password: password.

After the first login, let's configure a distinctive name for each unit and set a custom login and password. Go to the "Settings" → "General" section and configure:

  • Device Name (e.g., Master/Slave).

Go to the "Settings" → "Security" → "Change admin password" and configure:

  • Login (e.g., admin).

  • Password (e.g., admin).

Step 3: Firmware upgrade

Let's upgrade each unit to the latest stable firmware version. In case the laptop has an access to the Internet, a new software version will be detected automatically, update on both devices.

Otherwise, the manual firmware upgrade process should be performed:

  • Download latest release from the ftp server https://ftp.astrawireless.net/pub/Firmware.

  • In the "Maintenance" section click the "Select file" button and set the path to the downloaded file, or drug it to the specified area.

  • File will be uploaded to the device. Changes will take force after reboot.

Step 4: Radio parameters configuration

Let's configure the minimum needed radio parameters to establish the link.

At the both units, go to the "Settings" → "Radio" section and set this unit with:

  • Link ID parameter, it must be the same on both sides of the link

  • Center frequency use values selected at the Link Planning stage.

  • Channel width: use value selected at the Link Planning stage.

  • Power limit: set the minimum value in the range, as currently, we are in the lab, and we don't need high output power.

The rest of parameters remain with the default values.

Step 5: Check the wireless link status

Let's apply all settings described above for each unit and go to the "Dashboard" section and check if the device status has changed to "Connected".